| Problem |
Cause |
Solution |
| When igniter is pressed there is no
"ODS" pilot. |
Igniter electrode positioned wrong. |
*Replace
Pilot assembly |
|
Igniter electrode broken. |
*Replace
Pilot assembly |
|
Igniter electrode not connected to
igniter cable. |
*Replace igniter cable. |
|
Igniter cable pinched or wet |
*Free igniter cable if pinched by any metal or tubing. Keep
igniter cable dry. Replace cable if spark still isn't there after freeing the pinched wire |
| Flame seems to blow out. |
Air in the gas line. |
Purge air from line (Check to or will not light. ensure gas is going to pilot.) |
| Appliance produces odors. |
Stove burning vapors from paint, hair spray, glue, etc. |
Ventilate room. Stop using products while operating unit. |
| Gas leak. |
See warning label on cover. |
*Locate and correct all leaks |
| Gas odor even when control knob is in
"OFF" position. |
Gas leak. See warning label on cover. |
*Locate and correct all leaks. |
|
Control valve defective. |
*Replace control valve. |
| Smoke or odor during initial burn. |
Vapors from paint or production process. |
Unit curing out. Will stop. |
| Strong gas smell. |
LP fuel may have additives or be poor quality. |
*Shut off gas. Check supplier. |
|
Excess gas pressure. |
*Call utility company/installer. |
| Gas smell - sooting. |
Logs may be out of place. |
Compare placement of logs to the diagram in the manual. |
|
Orifice size may be incorrect. |
Replace if incorrect. |
| When igniter button is pressed, there is spark at ODS and no ignition. valve is closed. |
Gas supply turned off or manual shutoff. |
Turn on gas or open supply. |
|
Control knob not in "PILOT" position |
Correct knob position. |
|
Air in gas line when installed. |
Purge air from system by holding down control knob. Repeat ignition. |
|
"ODS" pilot is clogged. |
*Replace "ODS" assembly. |
|
Gas regulator setting is incorrect. |
*Replace gas regulator. |
| Pilot will not stay lit. |
Altitude is above 4000 ft.; ODS sensor requirement for air not satisfied |
Altitude is too high |
|
Defective thermopile |
*Replace thermopile |
|
Pilot orifice may be clogged |
*Clean out pilot orifice |
|
Defective valve magnet |
*Replace valve |
| "ODS" pilot lights, but flame dies when control knob is released |
Control knob not fully pressed in |
Press in knob completely |
|
Control knob not pressed in long enough |
Hold 30 sec. after pilot lights |
|
Manual shut-off valve not fully open |
Fully open shut-off valve |
| Pilot flame not touching thermopile, which causes it to cool and shut off the pilot flame. |
Low gas pressure |
*Contact gas supplier |
|
Dirty or clogged "ODS" pilot |
*Replace assembly or service |
|
Thermopile damaged |
*Replace thermopile |
|
Control valve damaged |
*Replace control valve |
| Flame too low |
Burner orifice clogged |
*Clean burner; replace orifice |
|
Orifice is too small |
*Replace orifice if necessary |
|
Inlet gas pressure too low |
*Contact gas supplier |
| Burner will not come on or has low flame (pilot is okay) |
Problem with gas pressure |
*Check gas pressure |
|
Control not on or is set on
"LOW" |
Move to "HIGH" setting |
|
Gas valve may be clogged due to debris entering valve during installation |
*Replace gas valve |
|
Faulty gas valve |
*Replace gas valve |
| Burner will not come on or has an Burner ports and/or carryover ports extremely low flame (pilot okay) |
may be clogged |
*Check and clean ports |
| Delayed ignition of burner |
Manifold pressure is too low |
*Contact gas supplier |
|
Burner or orifice is clogged |
*Check and clean both |
| Burner backfiring during ignition |
Orifice clogged or damaged |
*Clean and/or replace |
|
Burner damaged |
*Clean and/or replace |
| Burner will not come on |
Dirt on valve seal |
*Replace valve |
| Control knob frozen - will not turn |
Defective valve; foreign material |
*Replace valve |
| Carbon or sooting on logs. |
Logs out of position |
See log placement in manual |
|
Air holes on burner tube obstructed |
*Clean if necessary |
|
Gas type does not match stove |
Check designation on valve |
|
Oversized orifice |
*Change if necessary |
|
LP fuel may have additives |
*Check with gas supplier |
|
Gas pressure may be incorrect |